"PCSF_46007 No gateway connectivity is provided for domain. ERROR: Cannot connect to Integration Service" when running the PowerCenter 8.1 pmcmd connect command | |
| |
When running pmcmd connect command to connect to a domain, the following error is displayed:
The issue is not resolve even when the following command is used to update the Gateway node in the domains.infa file:
| |
| |
| |
To resolve the issue, add the environment variable INFA_DOMAINS_FILE. To add the environment variable, do the following: Windows:
UNIX:In a UNIX C shell environment, type the following:
In a UNIX Bourne shell environment, type the following:
| |
| |
|
Monday, February 11, 2008
"PCSF_46007 No gateway connectivity is provided for domain. ERROR: Cannot connect to Integration Service" when running the PowerCenter 8.1
Subscribe to:
Post Comments (Atom)
10 comments:
This is great information to solve this issue
Hi it does not resolve my issue and still gives the same error
That environmental variable is already set and is not the cause of the issue in my case. I am still unable to connect.
Hi it does notaddress my issue. I'm running 8.6.1.
Hi,
Its strange behaiviour sometimes, the variable takes only the path sometimes..\Informatica\PowerCenter8.6.1 or needs the file also \Informatica\PowerCenter8.6.1\domains.infa...both options worked on different envs for me.
also ensure that that the pmcmd's utility path is set in the PATH variable.
Gyan Shikha
pmcmd path is important :
if you have 8.6.1 then the value of environment variable should be -
INFA_DOMAINS_FILE-
C:\Informatica\PowerCenter8.6.1\domains.infa
quite valuable. resolved my issue.
hi i have a problem in access folder when connecting designer:
MSG is : Unable to access the folder
E:\system\clients\powerCenterClient\client\bin\Workspace\testfolder
i installed informatica 9.0.1 on E drive ,
Hi, I did added the env variable like variable Name :INFA_DOMAINS_FILE-
Variable Value =C:\Informatica\PowerCenter8.6.0\domains.infa
and added the path for PMCMD under path as C:\Informatica\PowerCenter8.6.0\server\bin Still I am getting the same error message as pasted below.Can some one help on this would be appreciated .
C:\Informatica\PowerCenter8.6.0\server\bin>pmcmd startworkflow -sv int_01 -d dom
ains -u Administrator -p Administrator -f sreenu WF_1_TGT_COUNTRY
Informatica(r) PMCMD, version [8.6.0], build [178.0613], Windows 32-bit
Copyright (c) Informatica Corporation 1994 - 2008
All Rights Reserved.
Invoked at Fri Mar 13 22:48:12 2015
[PCSF_46007] No gateway connectivity is provided for domain [domains].
ERROR: Cannot connect to Integration Service [int_01].
Completed at Fri Mar 13 22:48:12 2015
C:\Informatica\PowerCenter8.6.0\server\bin>
Post a Comment